Product Name:3A100 Series Pneumatic Solenoid Valve Product Model:3A110-M5 3A120-M5 3A110-06 3A120-06 Valve Type:Solenold Valve, Pneumatic Control Valve Brand:AirTAC Fluid: Air Position & Way Number:3 Port 2 Position Acting: Exterior Control
Model: |
3A110-M5 | 3A120-M5 | 3A110-06 | 3A120-06 |
Fluid: | Air(to be filtered by 40μm filter element) | |||
Acting: | Exterior Control | |||
Port Size: |
M5 |
PT1/8 | ||
Orifice Size: | 5.5mm²(Cv=0.31) | 12.0mm²(Cv=0.67) | ||
Valve Type: |
3 Port 2 Position |
|||
Operating Pressure: |
0.15~0.8MPa(21~114psi) |
|||
Proof Pressure: |
1.5MPa(215psi) |
|||
Temperature: |
-20~70 |
|||
Material of Body: |
Aluminum Alloy |
|||
Lubrication: | Not Required | |||
Max Frequency: | 5 Cycle/Sec |
① PT thread, NPT thread and G thread are available.
②Once lubricated air is used, continue with same medium to optimise valve life span. Lubricants like ISO VG32 or equivalent are recommended.
③The maximum actuation frequency is the no-load state.
1.Structure in sliding column mode: good tightness and sensitive reaction.
2.Double control solenoid valves have memory function.
3.Internal hole adopts special processing technology which has little attrition friction, low start pressure and long service life.
4.No need to add oil for lubrication.
5. Multi-mounting helps to install and apply.
6.It is available to form integrated valve group with the base to save installation space.
Installation & Usage:
1.Before installing, be sure the valve hasn't been damaged via transportation.
2.It's suggested to use the medium lubricated by 40μm filter element. Be aware of the flow direction and port size.
3.Please notice whether the installation condition accords with technical requirements (such as“act-uation frequency”, “working pressure” and “scope of application temperature”), then the equipment can be installed and used.
4.Notice the flow direction of air during installation, P is the air intake, A (B) is the work port and R (S) is the exhaust outlet.
5.Take measure to avoid vibration and frozen.
6.Firstly press the base gasket into the base, and then connect the base with the valve body by the affiliated screws. The base gasket can be pressed into the installation places that are not used temporarily, and then seal them with affiliated blank cap. When the system expands, take the blank cap off and install relative air valves;
7.To keep the dust away, please use the silencer for the exhaust ports. Never forget to install dirt-proof boot in air intake and outlet during dismounting.
3A11006NC | 3A12006 | 3A21006NO | 3A21008NC | 3A22008 | 3A31010NO |
3A11006NO | 3A21006NC | 3A22006 | 3A21008NO | 3A31010NC | 3A32010 |