Pneumatic Control Valve
4A110-M5 4A120-M5 4A130C-M5 4A130E-M5 4A130P-M5 4A100系列亚德客气控电磁阀
  • 4A110-06
  • 4A110-06-1
  • 4A110-M5
  • 4A120-06
  • 4A120-M5
4A110-M5 4A120-M5 4A130C-M5 4A130E-M5 4A130P-M5 4A100系列亚德客气控电磁阀

产品名称:4V400系列电磁阀
产品型号:4V430C-15 4V430E-15 4V430P-15
类型:电磁阀,气控阀
品牌: 亚德客(AiRTAC)
工作介质: 空气
位置数:五口二位
作动方式: 外部气控式



Download:
Specification:
型号: 4A110-M5 4A120-M5 4A130C-M5 4A130E-M5 4A130P-M5 
工作介质: 空气(经40μm以上滤网过滤)
作动方式: 外部气控式
接管口径: 进气=出气=M5
有效截面积: 5.5mm²(Cv=0.31) 5.0mm²(Cv=0.28)
位置数: 五口二位
五口三位
使用压力范围: 0.15~0.18MPa(21~114psi)
保证耐压力: 1.5MPa(215psi)
工作温度(℃) -20~70
本体材质: 铝合金
润滑: 不需要
最高作动频率: 5次/秒
3次/秒
重量: 85g 140g 165g

①接管牙型有NPT、G牙可供选择;
②如有加油润滑,中途不可停止,建议润滑油为ISO VG32或同级用油。
③最高动作频率为空载状态。

Product Feature:

1.Structure in sliding column mode: good tightness and sensitive reaction. 

2.Double control solenoid valves have memory function.

3.Internal hole adopts special processing technology which has little attrition friction, low start pressure and long service life.

4.No need to add oil for lubrication.
5. Multi-mounting helps to install and apply. 

6.It is available to form integrated valve group with the base to save installation space.

Installation & Usage:

1.Before installing, be sure the valve hasn't been damaged via transportation.

2.It's suggested to use the medium lubricated by 40μm filter element. Be aware of the flow direction and port size. 

3.Please notice whether the installation condition accords with technical requirements (such as“act-uation frequency”, “working pressure” and “scope of application temperature”), then the equipment can be installed and used. 

4.Notice the flow direction of air during installation, P is the air intake, A (B) is the work port and R (S) is the exhaust outlet. 

5.Take measure to avoid vibration and frozen.

6.Firstly press the base gasket into the base, and then connect the base with the valve body by the affiliated screws. The base gasket can be pressed into the installation places that are not used temporarily, and then seal them with affiliated blank cap. When the system expands, take the blank cap off and install relative air valves; 

7.To keep the dust away, please use the silencer for the exhaust ports. Never forget to install dirt-proof boot in air intake and outlet during dismounting. 


Order Code:
4A100 Series.jpg
Symbol:
6364940739986592426677864.jpg
4A130C06 4A130C06G 4A230E06G 4A330C10 4A11006
4A22008 4A130E06 4A230P06 4A42015 4A21006
4A22006 4A130P06 4A22008G 4A430C15 4A21008G
4A230E06 4A22006G 4A230C08 4A21008 4A31010G
4A12006 4A230C06 4A32010 4A31010 4A41015
Contact us
E-mail:info@fitsitech.com
Tel:+86-19928764188 
Add:Shangmei Times, 57 Longguan East Road, Tsinghua Community, Longhua Street, Longhua District, Shenzhen, China

     
Inquiry
Name:
E-mail:
Description:
CopyRight © 2010~2017 Shenzhen Fitsi Technology Co.,LTD All Right Reserved.     Sitemap    粤ICP备14001694号-由万创科技提供技术支持