Product Name:GVR Series Vacuum Regulator Product Model:GVR200-06 GVR200-08 GVR300-08 GVR300-10 Brand:AiRTAC Fluid: Air Pressure Range::-100~-1.3KPa Max. Pressure: -1.0KPa Temperature Range: -20~70℃
Model: |
GVR200-06 | GVR200-08 | GVR300-08 | GVR300-10 | |
Fluid: | Air | ||||
Port Size: | PT1/8 | PT1/4 | PT1/4 | PT3/8 | |
Pressure Range: | -100~-1.3KPa | ||||
Max. Pressure: | -1.0KPa | ||||
Air injalation consumption | 0.6L/min(ARN) and below | ||||
Temperature Range: | -20~70℃ | ||||
Weight: | 204 | 198 | 342 | 336 |
①NPT thread and G thread are available.
1. The pressed-in self-locking mechanism can prevent the abnormal movement of the set pressure caused by external interfere.
2. The pressure regulation is stable, the drift is small and the pressure characteristic is good.
3. In addition to panel installation, the bracket is optional for installation.
Installation & Usage:
1. please be used with safety circuit to avoid accidents when power failure, vacuum pump and vacuum regulator fail.
2. When checking. please set the pressure to o (atmospheric pressure) and completely cut off the pressure of the vacuum pump before pulling down the tube af the regulator.
3. The vacuum regulator can not be used to regulate the pressure of the vacuum pump. if the flow capacity of the vacuum generator is less than the now capacity of the vacuum regulator. it is not suitable as a vacuum source.
4. Tne regulating knob rotates clockwise, the atmospheric pressure changes to the vacuum pressure, turns counterclockwise, the vacuum pressure changes to atmospheric pressure.
5 After setting the pressure, press the button on the pressure adjusting button until you hear the click.
6. The vacuum regulator is used for negative pressure, and no positive pressure should be applied.