Products
PLC Programmable Controller
SIEMENS SIMATIC HMI 6AV2123-2MB03-0AX0 6AV2123-2GB03-0AX0 6AV2123-2JB03-0AX0 Basic Panel TFT display
  • 10328103024_1109016826
SIEMENS SIMATIC HMI 6AV2123-2MB03-0AX0 6AV2123-2GB03-0AX0 6AV2123-2JB03-0AX0 Basic Panel TFT display

Model Number: 6AV2123-2MB03-0AX0 6AV2123-2GB03-0AX0 6AV2123-2JB03-0AX0
Category: SIEMENS SIMATIC HMI
Place of Origin: Made in Germany	
Warranty: 12 month warranty



Download:
Specification:

SIMATIC HMI Basic Panel TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic V13, contains open-source software, which is provided free of charge

Product Feature:

SIMATIC HMI Basic Panel TFT display, 65536 colors, PROFINET interface, configurable from WinCC Basic V13/ STEP 7 Basic V13, contains open-source software, which is provided free of charge

Order Code:
General information
Product type designation KTP900 Basic color PN
Display
Design of display TFT widescreen display, LED backlighting
Screen diagonal 9 in
Display width 198 mm
Display height 111.7 mm
Number of colors 65536
Resolution (pixels)
● Horizontal image resolution
● Vertical image resolution
800 pixel
480 pixel
Backlighting
● MTBF backlighting (at 25 °C)
● Backlight dimmable
20 000 h
Yes
Control elements
Keyboard fonts
● Function keys
— Number of function keys 8
— Number of function keys with LEDs 0
● Keys with LED No
● System keys No
● Numeric keyboard Yes; Onscreen keyboard
● alphanumeric keyboard Yes; Onscreen keyboard
Touch operation
● Design as touch screen Yes; Analog-resistive
Installation type/mounting
Mounting position vertical
Mounting in portrait format possible Yes
Mounting in landscape format possible Yes
maximum permissible angle of inclination without external 35°
ventilation
Supply voltage
Type of supply voltage DC
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Input current
Current consumption (rated value) 230 mA
0.2 A²·s
Starting current inrush I²t
Power
Active power input, typ. 5.5 W
Processor
Processor type ARM
Memory
Flash Yes 
RAM Yes
Memory available for user data 10 Mbyte
Type of output
Acoustics
● Buzzer
● Speaker
No
No
Time of day
Clock
● Hardware clock (real-time)
● Software clock
● retentive
● synchronizable
Yes
Yes
Yes; Back-up duration typically 6 weeks
Yes
Interfaces
Number of industrial Ethernet interfaces 1
0
0
0
1; Up to 16 GB
0
0
0
0
No
Number of RS 485 interfaces
Number of RS 422 interfaces
Number of RS 232 interfaces
Number of USB interfaces
Number of 20 mA interfaces (TTY)
Number of parallel interfaces
Number of other interfaces
Number of SD card slots
With software interfaces
Industrial Ethernet
● Industrial Ethernet status LED 2
Protocols
PROFINET Yes
No
No
No
Yes
No
Supports protocol for PROFINET IO
IRT
PROFIBUS
EtherNet/IP
MPI
Protocols (Ethernet)
● TCP/IP
● DHCP
● SNMP
● DCP
● LLDP
Yes
Yes
Yes
Yes
Yes
WEB characteristics
● HTTP
● HTML
No
No
Redundancy mode
Media redundancy
— MRP No
Further protocols
● CAN
● MODBUS
No
Yes; Modicon (MODBUS TCP/IP)
Interrupts/diagnostics/status information
Diagnoses
● Diagnostic information readable No
EMC
Emission of radio interference acc. to EN 55 011
● Limit class A, for use in industrial areas Yes
● Limit class B, for use in residential areas No
Degree and class of protection
IP (at the front) IP65
IP20

Yes
Yes
IP (rear)
NEMA (front)
● Enclosure Type 4 at the front
● Enclosure Type 4x at the front
Standards, approvals, certificates
CE mark Yes
Yes
Yes
Yes
cULus
RCM (formerly C-TICK)
KC approval
Use in hazardous areas
● ATEX Zone 2
● ATEX Zone 22
● IECEx Zone 2
● IECEx Zone 22
● cULus Class I Zone 1
● cULus Class I Zone 2, Division 2
● FM Class I Division 2
No
No
No
No
No
No
No
Marine approval
● Germanischer Lloyd (GL)
● American Bureau of Shipping (ABS)
● Bureau Veritas (BV)
● Det Norske Veritas (DNV)
● Lloyds Register of Shipping (LRS)
● Nippon Kaiji Kyokai (Class NK)
● Polski Rejestr Statkow (PRS)
● Chinese Classification Society (CCS)
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Ambient conditions
Ambient temperature during operation
Operation (vertical installation)
— For vertical installation, min.
— For vertical installation, max.
0 °C
50 °C
Operation (max. tilt angle)
— At maximum tilt angle, min.
— At maximum tilt angle, max.
0 °C
40 °C
Operation (vertical installation, portrait format)
— For vertical installation, min.
— For vertical installation, max.
0 °C
40 °C
Operation (max. tilt angle, portrait format)
— At maximum tilt angle, min.
— At maximum tilt angle, max.
0 °C
35 °C
Ambient temperature during storage/transportation
● min.
● max.
-20 °C
60 °C
Relative humidity
● Operation, max. 90 %; no condensation
Operating systems
proprietary Yes
pre-installed operating system
● Windows CE No
configuration / header
Message indicator Yes
Yes
Yes
Yes
Yes
Alarm system (incl. buffer and acknowledgment)
Process value display (output)
Process value default (input) possible
Recipe management
Configuration software
● STEP 7 Basic (TIA Portal)
● STEP 7 Professional (TIA Portal)
● WinCC flexible Compact
● WinCC flexible Standard
● WinCC flexible Advanced
● WinCC Basic (TIA Portal)
● WinCC Comfort (TIA Portal)
● WinCC Advanced (TIA Portal)
● WinCC Professional (TIA Portal)
Yes; via integrated WinCC Basic (TIA Portal)
Yes; via integrated WinCC Basic (TIA Portal)
No
No
No
Yes
Yes
Yes
Yes
Languages
Online languages
● Number of online/runtime languages 10
Project languages
● Languages per project 32
Functionality under WinCC (TIA Portal)
Libraries Yes
Yes
Yes; Available with WinCC (TIA Portal) V14 or higher
No
Yes
No
Yes
Yes
500
Applications/options
● Web browser
● SIMATIC WinCC Sm@rtServer
Number of Visual Basic Scripts
Task planner
● time-controlled
● task-controlled
Help system
● Number of characters per info text
Message system
● Number of alarm classes
● Bit messages
— Number of bit messages
● Analog messages
— Number of analog messages
● S7 alarm number procedure
● System messages HMI
● System event, more (SIMATIC S7, SINUMERIK, SIMOTION, ... )
● Number of characters per message
● Number of process values per message
● Acknowledgment groups
● Message indicator
● Message buffer
— Number of entries
— Circulating buffer
— retentive
— maintenance-free
32
1 000
25
No
Yes
Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
80
8
Yes
Yes
256
Yes
Yes
Yes
Recipe management
● Number of recipes
● Data records per recipe
● Entries per data record
● Size of internal recipe memory
● Recipe memory expandable
50
100
100
256 kbyte No
Variables
● Number of variables per device
● Number of variables per screen
● Limit values
● Multiplexing
● Structures
● Arrays
800
100
Yes
Yes
No
Yes
Images
● Number of configurable images
● Permanent window/default
250
Yes
● Global image
● Pop-up images
● Slide-in images
● Image selection by PLC
● Image number in the PLC
Yes
No
No
Yes
Yes
Image objects
● Number of objects per image
● Text fields
● I/O fields
● Graphic I/O fields (graphics list)
● Symbolic I/O fields (text list)
● Date/time fields
● Switches
● Buttons
● Graphic display
● Icons
● Geometric objects
100
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Complex image objects
● Number of complex objects per screen
● Alarm view
● Trend view
● User view
● Status/control
● Sm@rtClient view
● Recipe view
● f(x) trend view
● System diagnostics view
● Media Player
● HTML browser
● PDF display
● IP camera display
● Bar graphs
● Sliders
● Pointer instruments
● Analog/digital clock
10
Yes
Yes
Yes
No
No
Yes
No
Yes; System message buffer of the SIMATIC S7-1200 and S7-1500
No
Yes
No
No
Yes
No
No
No
Lists
● Number of text lists per project
● Number of entries per text list
● Number of graphics lists per project
● Number of entries per graphics list
300
100
100
100
Archiving
● Number of archives per device
● Number of entries per archive
● Message archive
● Process value archive
● Archiving methods
— Sequential archive
— Short-term archive
● Memory location
— Memory card
— USB memory
— Ethernet
● Data storage format
— CSV
— TXT
— RDB
2;
One message and one process value archive
10
000
Yes
Yes
Yes
Yes
No
Yes
No
No
Yes
No
Security
● Number of user groups
● Number of user rights
● Number of users
50
32
50
● Password export/import
● SIMATIC Logon
Yes
No
Character sets
● Keyboard fonts
— US English
Yes
Transfer (upload/download)
● MPI/PROFIBUS DP
● USB
● Ethernet
● using external storage medium
No
No
Yes
Yes
Process coupling
● S7-1200
● S7-1500
● S7-200
● S7-300/400
● LOGO!
● WinAC
● SINUMERIK
● SIMOTION
● Allen Bradley (EtherNet/IP)
● Allen Bradley (DF1)
● Mitsubishi (MC TCP/IP)
● Mitsubishi (FX)
● OMRON (FINS TCP)
● OMRON (LINK/Multilink)
● Modicon (Modbus TCP/IP)
● Modicon (Modbus)
Yes
Yes
Yes
Yes
Yes
Yes
Yes;
No access to NCK data
Yes
Yes
No
Yes
No
No
No
Yes
No
Service tools/configuration aids
● Backup/Restore manually
● Backup/Restore automatically
● Simulation
● Device switchover
Yes
No
Yes
Yes
Peripherals/Options
Printer No
No
No
No
Yes
Yes
Yes
SIMATIC HMI MM memory card: Multi Media Card
SIMATIC HMI SD memory card: Secure Digital memory card
SIMATIC HMI CF memory card Compact Flash Card
USB memory
SIMATIC IPC USB Flashdrive (USB stick)
SIMATIC HMI USB stick
Mechanics/material
Enclosure material (front)
● Plastic
● Aluminum
● Stainless steel

Yes
No
No
Dimensions
Width of the housing front 267 mm

Height of housing front 182 mm
Mounting cutout, width 251 mm
Mounting cutout, height 166 mm
Overall depth 55 mm
Weights
Weight (without packaging) 1 130 g
Weight (with packaging) 1 393 g


Symbol:
Contact us
E-mail:info@fitsitech.com
Tel:+86-19928764188 
Add:Shangmei Times, 57 Longguan East Road, Tsinghua Community, Longhua Street, Longhua District, Shenzhen, China

     
Inquiry
Name:
E-mail:
Description:
CopyRight © 2010~2017 Shenzhen Fitsi Technology Co.,LTD All Right Reserved.     Sitemap    粤ICP备14001694号-由万创科技提供技术支持