Model Number: 6ES7288-1CR20-0AA1 6ES7288-1CR40-0AA1 6ES7288-1ST20-0AA0 6ES7288-1ST30-0AA0 6ES7288-1ST40-0AA0 Category: SIEMENS SIMATIC S7-200 SMART Product Type: PLC Module Type: Industry Automation Place of Origin: Made in Germany Warranty: 12 month warranty
SIMATIC S7-200 SMART CPU CR20s, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 12 DI 24V DC; 8 DO RELAY 2A; POWER SUPPLY: AC, 85 - 264 V AC AT 47 - 63 HZ, PROGRAM/DATA MEMORY: 20 KB
SIMATIC S7-200 SMART CPU CR20s, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 12 DI 24V DC; 8 DO RELAY 2A; POWER SUPPLY: AC, 85 - 264 V AC AT 47 - 63 HZ, PROGRAM/DATA MEMORY: 20 KB
General information | |
Product type designation | CPU CR20 AC/DC/relay |
Engineering with | |
● Programming package | STEP 7 Micro/WIN SMART |
Installation type/mounting | |
Rail mounting | Yes; Standard - DIN rail |
Supply voltage | |
Rated value (AC) ● 120 V AC ● 230 V AC |
230 V; 230 V AC (L1, N) Yes; 85 to 132 V AC Yes; 170 to 264 V AC |
permissible range, lower limit (AC) | 85 V |
permissible range, upper limit (AC) | 264 V |
Reverse polarity protection | No |
Line frequency | |
● permissible range, lower limit ● permissible range, upper limit |
47 Hz 63 Hz |
Load voltage L+ | |
● Rated value (DC) ● permissible range, lower limit (DC) ● permissible range, upper limit (DC) |
24 V 5 V 250 V |
Input current | |
Current consumption (rated value) |
60 mA; At 220 V AC 80 mA; At 220 V AC 16.3 A; at 264 V |
Current consumption, max. | |
Inrush current, max. | |
Power loss | |
Power loss, max. | 6 W |
Memory | |
Type of memory | DDR |
Flash | Yes |
RAM | Yes |
Micro Memory Card | No |
CPU processing times | |
for bit operations, typ. | 150 ns; / instruction |
for word operations, typ. | 1.2 µs; / instruction |
for floating point arithmetic, typ. | 3.6 µs; / instruction |
Hardware configuration | |
Integrated power supply | No |
Time of day | |
![]() |
|
● Type ● Hardware clock (real-time) |
Software clock No |
Digital inputs | |
Number of digital inputs ● of which inputs usable for technological functions |
12; Integrated 4; HSC: 4 @ 100 kHz single phase, 2 @ 50 kHz A/B phase |
Source/sink input | Yes |
Input voltage | |
● Type of input voltage ● Rated value (DC) ● for signal "0" ● for signal "1" |
DC 24 V; DC at 4 mA nominal < 5 V DC +15 to +30 V |
Input current | |
● for signal "0", max. (permissible quiescent current) ● for signal "1", typ. |
1 mA 4 mA |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable — at "0" to "1", min. — at "0" to "1", max. |
Yes; 0.2 µs, 0.4 µs, 0.8 µs, 1.6 µs, 3.2 µs, 6.4 µs and 12.8 µs, selectable in 4 groups 0.2 µs 12.8 µs |
for interrupt inputs | |
— parameterizable | Yes |
Cable length | |
● shielded, max. ● unshielded, max. |
500 m; Standard input: 500 m, high-speed counters: 50 m 300 m |
Digital outputs | |
Number of digital outputs | 8; Relays |
Switching capacity of the outputs | |
● with resistive load, max. ● on lamp load, max. |
2 A 30 W; 30 W with DC, 200 W with AC |
Output delay with resistive load | |
● "0" to "1", max. ● "1" to "0", max. |
10 ms; max. 10 ms; max. |
Switching frequency | |
● of the pulse outputs, with resistive load, max. | 1 Hz |
Relay outputs | |
● Number of relay outputs ● Number of operating cycles, max. |
8 10 000 000; mechanically 10 million, at rated load voltage 100 000 |
Cable length | |
● shielded, max. ● unshielded, max. |
500 m 300 m |
Interfaces | |
Number of industrial Ethernet interfaces | 0 |
Number of RS 485 interfaces | 1 |
Optical interface | No |
1. Interface | |
Interface type |
RS 485 (max. 187.5 kbps) |
Isolated | Yes; 500 V AC or 707 V DC |
Interface types | |
● RS 485 ● Design of the connection |
Yes 9-pin sub D socket |
Protocols | |
Supports protocol for PROFINET IO | No |
PROFIBUS | No |
Protocols (Ethernet) | |
● TCP/IP | No |
EMC | |
Interference immunity against discharge of static electricity | |
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 — Test voltage at air discharge — Test voltage at contact discharge |
Yes 8 kV 4 kV |
Interference immunity against high-frequency electromagnetic fields | |
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-3 — Frequency range of the RF radiation |
Yes; 10 V/m, 80 to 1 000 MHz (to IEC 61000-4-3); 10 V/m, 900 MHz, 1.89 GHz, 50% ED (to IEC 61000-4-3) 10 V/m for 80 MHz ~ 1 GHz, 3 V/m for 1.4 GHz ~ 2 GHz, 3 V/m for 87 MHz ~ 108 MHz, 174 MHz ~ 230 MHz, 470 MHz ~ 790 MHz, 1.4 GHz ~ 2 GHz, 1 V/m for 2 GHz ~ 2.7 GHz |
Interference immunity to cable-borne interference | |
● Interference immunity on supply lines acc. to IEC 61000-4-4 ● Interference immunity on signal cables acc. to IEC 61000-4-4 |
Yes; ±2 kV acc. to IEC 61000-4-4, burst; surge measurements with additional protective elements Yes; ±2 kV acc. to IEC 61000-4-4, Burst |
Interference immunity against voltage surge | |
● Interference immunity on supply lines acc. to IEC 61000-4-5 ● asymmetric interference — Test voltage on supply cables — Test voltage on signal cables >30m |
Yes; ±1 kV (acc. to IEC 61000-4-5; 1995; surge symm.), ±2 kV (acc. to IEC 61000-4-5; 1995; surge asymm.), no external protective circuit required 2 kV 2 kV |
Interference immunity against conducted variable disturbance induced by high-frequency fields | |
● Interference immunity against high frequency current feed acc. to IEC 61000-4-6 | Yes; 10 V, 150 kHz to 80 MHz (to IEC 61000-4-6) |
Emission of radio interference acc. to EN 55 011 | |
● Limit class A, for use in industrial areas | Yes; Emission of radio interference acc. to EN 61000-6-4 +A1 for use in industrial environments |
Emission of conducted and non-conducted interference | |
● Interference emission via line/AC current cables | EN 61000-6-4, interference emission: Intended for use in industrial areas. |
Degree and class of protection | |
IP degree of protection | IP20 |
Standards, approvals, certificates | |
CE mark | Yes |
Ambient conditions | |
Free fall | |
● Fall height, max. | 0.5 m; five times, in product package |
Ambient temperature during operation | |
● min. ● max. ● horizontal installation, min. ● horizontal installation, max. ● vertical installation, min. ● vertical installation, max. |
0 °C 55 °C 0 °C 55 °C 0 °C 45 °C |
Ambient temperature during storage/transportation | |
● min. ● max. |
-40 °C 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
● Storage/transport, min. ● Storage/transport, max. |
660 hPa 1 080 hPa |
Altitude during operation relating to sea level | |
● Installation altitude, min. ● Installation altitude, max. |
-1 000 m 2 000 m |
Relative humidity | |
● Operation at 25 ℃ without condensation, max. | 95 % |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD — FBD — STL |
Yes Yes Yes |
Dimensions | |
Width | 90 mm |
Height | 100 mm |
Depth | 81 mm |
Weights | |
Weight, approx. | 365 g; approx. |
6ES7288-1CR20-0AA1 | 6ES7288-1CR40-0AA1 | 6ES7288-1ST20-0AA0 |
6ES7288-1ST30-0AA0 | 6ES7288-1ST40-0AA0 | 6ES7288-1ST60-0AA0 |
6ES7288-1CR40-0AA0 | 6ES7288-1CR60-0AA0 | 6ES7288-1SR40-0AA0 |
6ES7288-1SR60-0AA0 | 6ES7288-1SR20-0AA0 | 6ES7288-1SR30-0AA0 |
6ES7288-1ST20-0AA1 | 6ES7288-1ST60-0AA1 | 6ES7288-1ST40-0AA1 |
6ES7288-1SR60-0AA1 | 6ES7288-1SR30-0AA1 | 6ES7288-1SR20-0AA1 |
6ES7288-1SR40-0AA1 | 6ES7288-1ST30-0AA1 | 6ES7288-1SR20-0AA1 |
6ES7288-5DT04-0AA0 | 6ES7288-5BA01-0AA0 | 6ES7288-1ST20-0AA0 |
6ES7288-1ST60-0AA0 | 6ES7288-1SR40-0AA0 | 6ES7288-1SR30-0AA0 |
6ES7288-1SR20-0AA0 | 6ES7288-5AQ01-0AA0 | 6ES7288-1ST40-0AA0 |
6ES7288-1ST30-0AA0 | 6ES7288-1CR40-0AA0 | 6ES7288-1SR60-0AA0 |
6ES7288-1CR60-0AA1 | 6ES7288-5AE01-0AA0 | 6ES7288-1CR60-0AA0 |
6ES7288-1CR30-0AA1 | 6ES7288-6EC01-0AA0 | 6ES7288-5CM01-0AA0 |
6ES7288-5DT04-0AA0 | 6ES7288-5AE01-0AA0 | 6ES7288-5AQ01-0AA0 |
6ES7288-5BA01-0AA0 |