Model Number: 6ES7211-1BE40-0XB0 6ES7211-1AE40-0XB0 6ES7212-1HF42-4YB1 6ES7217-1AG40-0XB0 6ES7215-1HG40-0XB0 Category: SIEMENS SIMATIC S7-1200F CPU Product Type: PLC Type: Industry Automation Place of Origin: Made in Germany Warranty: 12 month warranty
SIMATIC S7-1200, CPU 1211C, compact CPU, AC/DC/relay, onboard I/O: 6 DI 24 V DC; 4 DO relay 2A; 2 AI 0-10 V DC, Power supply: AC 85-264 V AC at 47-63 Hz, Program/data memory 50 KB
SIMATIC S7-1200, CPU 1211C, compact CPU, AC/DC/relay, onboard I/O: 6 DI 24 V DC; 4 DO relay 2A; 2 AI 0-10 V DC, Power supply: AC 85-264 V AC at 47-63 Hz, Program/data memory 50 KB
General information | |
Product type designation | CPU 1211C AC/DC/relay |
Firmware version | V4.5 |
Engineering with | |
● Programming package | STEP 7 V17 or higher |
Supply voltage | |
Rated value (AC) ● 120 V AC ● 230 V AC |
Yes Yes |
permissible range, lower limit (AC) | 85 V |
permissible range, upper limit (AC) | 264 V |
Line frequency | |
● permissible range, lower limit ● permissible range, upper limit |
47 Hz 63 Hz |
Input current | |
Current consumption (rated value) | 60 mA at 120 V AC; 30 mA at 240 V AC |
Current consumption, max. | 180 mA at 120 V AC; 90 mA at 240 V AC |
Inrush current, max. | 20 A; at 264 V |
I²t | 0.8 A²·s |
Output current | |
for backplane bus (5 V DC), max. | 750 mA; Max. 5 V DC for CM |
Encoder supply | |
24 V encoder supply | |
● 24 V | 20.4 to 28.8V |
Power loss | |
Power loss, typ. | 10 W |
Memory | |
Work memory | |
● integrated ● expandable |
50 kbyte No |
Load memory | |
● integrated ● Plug-in (SIMATIC Memory Card), max. |
1 Mbyte with SIMATIC memory card |
Backup | |
● present ● maintenance-free ● without battery |
Yes Yes Yes |
CPU processing times | |
for bit operations, typ. | 0.08 µs; / instruction |
for word operations, typ. | 1.7 µs; / instruction |
for floating point arithmetic, typ. | 2.3 µs; / instruction |
CPU-blocks | |
Number of blocks (total) | DBs, FCs, FBs, counters and timers. The maximum number of addressable blocks ranges from 1 to 65535. There is no restriction, the entire working memory can be used |
OB | |
● Number, max. | Limited only by RAM for code |
Data areas and their retentivity | |
Retentive data area (incl. timers, counters, flags), max. | 14 kbyte |
Flag | |
● Size, max. | 4 kbyte; Size of bit memory address area |
Local data | |
● per priority class, max. | 16 kbyte; Priority class 1 (program cycle): 16 KB, priority class 2 to 26: 6 KB |
Address area | |
Process image | |
● Inputs, adjustable ● Outputs, adjustable |
1 kbyte 1 kbyte |
Hardware configuration | |
Number of modules per system, max. | 3 communication modules, 1 signal board |
Time of day | |
Clock | |
● Hardware clock (real-time) ● Backup time ● Deviation per day, max. |
Yes 480 h; Typical ±60 s/month at 25 °C |
Digital inputs | |
Number of digital inputs ● of which inputs usable for technological functions |
6; Integrated 6; HSC (High Speed Counting) |
Source/sink input | Yes |
Number of simultaneously controllable inputs | |
all mounting positions | |
— up to 40 °C, max. | 6 |
Input voltage | |
● Rated value (DC) ● for signal "0" ● for signal "1" |
24 V 5 V DC at 1 mA 15 V DC at 2.5 mA |
Input current | |
● for signal "1", typ. | 4 mA; nominal |
Input delay (for rated value of input voltage) | |
for standard inputs | |
— parameterizable — at "0" to "1", min. — at "0" to "1", max. |
0.2 ms, 0.4 ms, 0.8 ms, 1.6 ms, 3.2 ms, 6.4 ms and 12.8 ms, selectable in groups of four 0.2 ms 12.8 ms |
for interrupt inputs | |
— parameterizable | Yes |
for technological functions | |
— parameterizable | Single phase : 3 @ 100 kHz, differential: 3 @ 80 kHz |
Cable length | |
● shielded, max. ● unshielded, max. |
500 m; 50 m for technological functions 300 m; for technological functions: No |
Digital outputs | |
Number of digital outputs | 4; Relays |
Switching capacity of the outputs | |
● with resistive load, max. ● on lamp load, max. |
2 A 30 W with DC, 200 W with AC |
Output delay with resistive load | |
● "0" to "1", max. ● "1" to "0", max. |
10 ms; max. 10 ms; max. |
Relay outputs | |
● Number of relay outputs ● Number of operating cycles, max. |
4 mechanically 10 million, at rated load voltage 100 000 |
Cable length | |
● shielded, max. ● unshielded, max. |
500 m 150 m |
Analog inputs | |
Number of analog inputs | 2 |
Input ranges | |
● Voltage | Yes |
Input ranges (rated values), voltages | |
● 0 to +10 V — Input resistance (0 to 10 V) |
Yes ≥100k ohms |
Cable length | |
● shielded, max. | 100 m; twisted and shielded |
Analog outputs | |
Number of analog outputs | 0 |
Analog value generation for the inputs | |
Integration and conversion time/resolution per channel | |
● Resolution with overrange (bit including sign), max. ● Integration time, parameterizable ● Conversion time (per channel) |
10 bit Yes 625 µs |
Encoder | |
Connectable encoders | |
● 2-wire sensor | Yes |
1. Interface | |
Interface type | PROFINET |
Isolated | Yes |
automatic detection of transmission rate | Yes |
Autonegotiation | Yes |
Autocrossing | Yes |
Interface types | |
● RJ 45 (Ethernet) ● Number of ports ● integrated switch |
Yes 1 No |
Protocols | |
● PROFINET IO Controller ● PROFINET IO Device ● SIMATIC communication ● Open IE communication ● Web server ● Media redundancy |
Yes Yes Yes Yes; Optionally also encrypted Yes No |
PROFINET IO Controller | |
● Transmission rate, max. | 100 Mbit/s |
Services | |
— PG/OP communication — Isochronous mode — IRT — PROFIenergy — Prioritized startup — Number of IO devices with prioritized startup, max. — Number of connectable IO Devices, max. — Number of connectable IO Devices for RT, max. — of which in line, max. — Activation/deactivation of IO Devices — Number of IO Devices that can be |
Yes; encryption with TLS V1.3 pre-selected No No No Yes 16 16 16 16 Yes 8 |
simultaneously activated/deactivated, max. — Updating time |
The minimum value of the update time also depends on the communication component set for PROFINET IO, on the number of IO devices and the quantity of configured user data. |
PROFINET IO Device | |
Services | |
— PG/OP communication — Isochronous mode — IRT — PROFIenergy — Shared device — Number of IO Controllers with shared device, max. |
Yes; encryption with TLS V1.3 pre-selected No No Yes Yes 2 |
Protocols | |
Supports protocol for PROFINET IO |
Yes |
PROFIsafe | No |
PROFIBUS | Yes; CM 1243-5 (master) or CM 1242-5 (slave) required |
OPC UA | Yes; OPC UA Server |
AS-Interface | Yes; CM 1243-2 required |
Protocols (Ethernet) | |
● TCP/IP ● DHCP ● SNMP ● DCP ● LLDP |
Yes No Yes Yes Yes |
Redundancy mode | |
Media redundancy | |
— MRP — MRPD |
No No |
SIMATIC communication | |
● S7 routing | Yes |
Open IE communication | |
● TCP/IP — Data length, max. — several passive connections per port, supported ● ISO-on-TCP (RFC1006) — Data length, max. ● UDP — Data length, max. |
Yes 8 kbyte Yes Yes 8 kbyte Yes 1 472 byte |
Web server | |
● supported ● User-defined websites |
Yes Yes |
OPC UA | |
● Runtime license required ● OPC UA Server — Application authentication — User authentication — Number of sessions, max. — Number of subscriptions per session, max. — Sampling interval, min. — Publishing interval, min. — Number of server methods, max. — Number of monitored items, max. — Number of server interfaces, max. — Number of nodes for user-defined server interfaces, max. |
Yes; "Basic" license required Yes; data access (read, write, subscribe), method call, runtime license required Available security policies: None, Basic128Rsa15, Basic256Rsa15, Basic256Sha256 "anonymous" or by user name & password 10 50 100 ms 200 ms 20 1 000 2 2 000 |
Further protocols | |
● MODBUS | Yes |
communication functions / header | |
S7 communication | |
● supported ● as server ● as client ● User data per job, max. |
Yes Yes Yes See online help (S7 communication, user data size) |
Number of connections | |
● overall | PG Connections: 4 reserved / 4 max; HMI Connections: 12 reserved / 18 max; S7 Connections: 8 reserved / 14 max; Open User Connections: 8 reserved / 14 max; Web Connections: 2 reserved / 30 max; OPC UA Connections: 0 reserved / 10 max; Total Connections: 34 reserved / 64 max |
Test commissioning functions | |
Status/control | |
● Status/control variable ● Variables |
Yes Inputs/outputs, memory bits, DBs, distributed I/Os, timers, counters |
Forcing | |
● Forcing | Yes |
Diagnostic buffer | |
● present | Yes |
Traces | |
● Number of configurable Traces ● Memory size per trace, max. |
2 512 kbyte |
Interrupts/diagnostics/status information | |
Diagnostics indication LED | |
● RUN/STOP LED ● ERROR LED ● MAINT LED |
Yes Yes Yes |
Integrated Functions | |
Counter ● Number of counters ● Counting frequency, max. |
6 100 kHz Yes |
Frequency measurement | Yes |
controlled positioning | Yes |
Number of position-controlled positioning axes, max. | 8 |
Number of positioning axes via pulse-direction interface | Up to 4 with SB 1222 |
PID controller | Yes |
Number of alarm inputs | 4 |
Potential separation | |
Potential separation digital inputs | |
● Potential separation digital inputs ● between the channels, in groups of |
500V AC for 1 minute 1 |
Potential separation digital outputs | |
● Potential separation digital outputs ● between the channels ● between the channels, in groups of |
Relays No 1 |
EMC | |
Interference immunity against discharge of static electricity | |
● Interference immunity against discharge of static electricity acc. to IEC 61000-4-2 — Test voltage at air discharge — Test voltage at contact discharge |
Yes 8 kV 6 kV |
Interference immunity to cable-borne interference | |
● Interference immunity on supply lines acc. to IEC 61000-4-4 ● Interference immunity on signal cables acc. to IEC 61000-4-4 |
Yes Yes |
Interference immunity against voltage surge | |
● Interference immunity on supply lines acc. to IEC 61000-4-5 | Yes |
Interference immunity against conducted variable disturbance induced by high-frequency fields | |
● Interference immunity against high-frequency radiation acc. to IEC 61000-4-6 | Yes |
Emission of radio interference acc. to EN 55 011 | |
● Limit class A, for use in industrial areas ● Limit class B, for use in residential areas |
Yes; Group 1 Yes; When appropriate measures are used to ensure compliance with the limits for Class B according to EN 55011 |
Degree and class of protection | |
IP degree of protection | IP20 |
Standards, approvals, certificates | |
CE mark | Yes |
UL approval | Yes |
cULus | Yes |
FM approval | Yes |
RCM (formerly C-TICK) | Yes |
KC approval | Yes |
Marine approval | Yes |
Ambient conditions | |
Free fall | |
● Fall height, max. | 0.3 m; five times, in product package |
Ambient temperature during operation | |
● min. ● max. ● horizontal installation, min. ● horizontal installation, max. ● vertical installation, min. ● vertical installation, max. |
-20 °C 60 °C -20 °C 60 °C -20 °C 50 °C |
Ambient temperature during storage/transportation | |
● min. ● max. |
-40 °C 70 °C |
Air pressure acc. to IEC 60068-2-13 | |
● Operation, min. ● Operation, max. ● Storage/transport, min. ● Storage/transport, max. |
795 hPa 1 080 hPa 660 hPa 1 080 hPa |
Altitude during operation relating to sea level | |
● Installation altitude, min. ● Installation altitude, max. |
-1 000 m 5 000 m; Restrictions for installation altitudes > 2 000 m, see manual |
Relative humidity | |
● Operation, max. | 95 %; no condensation |
Vibrations | |
● Vibration resistance during operation acc. to IEC 60068-2-6 ● Operation, tested according to IEC 60068-2-6 |
2 g (m/s²) wall mounting, 1 g (m/s²) DIN rail Yes |
Shock testing | |
● tested according to IEC 60068-2-27 | Yes; IEC 68, Part 2-27 half-sine: strength of the shock 15 g (peak value), duration 11 ms |
Pollutant concentrations | |
● SO2 at RH < 60% without condensation | S02: < 0.5 ppm; H2S: < 0.1 ppm; RH < 60% condensation-free |
configuration / header | |
configuration / programming / header | |
Programming language | |
— LAD — FBD — SCL |
Yes Yes Yes |
Know-how protection | |
● User program protection/password protection ● Copy protection ● Block protection |
Yes Yes Yes |
Access protection | |
● protection of confidential configuration data | Yes |
![]() |
|
● Protection level: Write protection ● Protection level: Read/write protection ● Protection level: Complete protection |
Yes Yes Yes |
programming / cycle time monitoring / header | |
● cycle monitoring time / adjustable | Yes |
Dimensions | |
Width | 90 mm |
Height | 100 mm |
Depth | 75 mm |
Weights | |
Weight, approx. | 420 g |
6ES7214-1AF40-0XB0 | 6ES7212-1AE40-0XB0 | 6ES7214-1HF40-0XB0 |
6ES7212-1HF40-0XB0 | 6ES7212-1AF40-0XB0 | 6ES7215-1HF40-0XB0 |
6ES7215-1AF40-0XB0 | 6ES7211-1HE40-0XB0 | 6ES7212-1BE40-0XB0 |
6ES7212-1HE40-0XB0 | 6ES7211-1BE40-0XB0 | 6ES7211-1AE40-0XB0 |
6ES7212-1HF42-4YB1 | 6ES7217-1AG40-0XB0 | 6ES7215-1HG40-0XB0 |
6ES7215-1AG40-0XB0 | 6ES7214-1BG40-0XB0 | 6ES7214-1HG40-0XB0 |
6ES7212-1HF41-4YB1 | 6ES7214-1AG40-0XB0 | 6ES7215-1BG40-0XB0 |