Model Number: 6ES7317-7UL10-0AB0 6ES7315-7TJ10-0AB0 6ES7318-3FL01-0AB0 6ES7317-7TK10-0AB0 Category: SIEMENS SIMATIC S7-300 CPU Product Type: CPU Type: Industry Automation Place of Origin: Made in Germany Warranty: 12 month warranty
SIMATIC S7-300, CPU 317TF-3 PN/DP, Central processing unit for PLC, Technology and safety tasks, 1.5 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP (drive), 3rd interface Ethernet PROFINET with 2-port switch, Integr. I/O for technology, Front connector (1x 40-pole) and Micro Memory Card min. 8 MB required
SIMATIC S7-300, CPU 317TF-3 PN/DP, Central processing unit for PLC, Technology and safety tasks, 1.5 MB work memory, 1st interface MPI/DP 12 Mbit/s, 2nd interface DP (drive), 3rd interface Ethernet PROFINET with 2-port switch, Integr. I/O for technology, Front connector (1x 40-pole) and Micro Memory Card min. 8 MB required
General information | |||
HW functional status |
01 |
||
Firmware version | CPU: V3.2; integrated technology V4.1.5 | ||
Product function | |||
● Isochronous mode | Yes; Via PROFIBUS DP or PROFINET interface | ||
Engineering with | |||
● Programming package | STEP 7 V5.5 SP2 or higher; S7-Technology option package V4.2 SP3 or higher, Distributed Safety V5.4 SP5 or higher, S7-F Configuration Pack V5.5 SP10 or higher | ||
Supply voltage | |||
Rated value (DC) | 24 V | ||
permissible range, lower limit (DC) | 19.2 V | ||
permissible range, upper limit (DC) | 28.8 V | ||
external protection for power supply lines (recommendation) | 2 A min. | ||
Load voltage L+ | |||
● Rated value (DC) ● Reverse polarity protection |
24 V Yes |
||
Digital outputs | |||
— Rated value (DC) — Reverse polarity protection |
24 V; 2L+ No; 2L+ |
||
Input current | |||
Current consumption (rated value) | 1 100 mA | ||
Current consumption (in no-load operation), typ. | 270 mA | ||
Inrush current, typ. | 6.5 A | ||
I²t | 1 A²·s | ||
Power loss | |||
Power loss, typ. | 8.5 W | ||
Memory | |||
Work memory | |||
● integrated ● expandable |
1 536 kbyte No |
||
Load memory | |||
● Plug-in (MMC) ● Plug-in (MMC), max. ● Data management on MMC (after last programming), min. |
Yes 8 Mbyte 10 y |
||
Backup | |||
● present ● without battery |
Yes; Guaranteed by MMC (maintenance-free) Yes; Program and data |
||
CPU processing times | |||
for bit operations, typ. | 0.025 µs | ||
for word operations, typ. | 0.03 µs | ||
for fixed point arithmetic, typ. | 0.04 µs | ||
for floating point arithmetic, typ. | 0.16 µs | ||
CPU-blocks | |||
Number of blocks (total) | 2 048; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. | ||
DB | |||
● Number, max. ● Size, max. |
2 048; Number range: 1 to 16000 64 kbyte |
||
FB | |||
● Number, max. ● Size, max. |
2 048; Number range: 0 to 7999 64 kbyte |
||
FC | |||
● Number, max. ● Size, max. |
2 048; Number range: 0 to 7999 64 kbyte |
||
OB | |||
● Number, max. ● Size, max. ● Number of free cycle OBs ● Number of time alarm OBs ● Number of delay alarm OBs ● Number of cyclic interrupt OBs ● Number of process alarm OBs ● Number of DPV1 alarm OBs ● Number of isochronous mode OBs ● Number of technology synchronous alarm OBs ● Number of startup OBs ● Number of asynchronous error OBs ● Number of synchronous error OBs |
see instruction list 64 kbyte 1; OB 1 1; OB 10 2; OB 20, 21 4; OB 32, 33, 34, 35 1; OB 40 3; OB 55, 56, 57 1; OB 61 - isochronous mode is possible either on DP or PROFINET IO (not simultaneously) 1; OB 65 1; OB 100 6; OB 80, 82, 83, 85, 86, 87 (OB83 only for PROFINET IO) 2; OB 121, 122 |
||
Nesting depth | |||
● per priority class ● additional within an error OB |
16 4 |
||
Counters, timers and their retentivity | |||
S7 counter | |||
● Number | 512 | ||
Retentivity | |||
— adjustable — lower limit — upper limit — preset |
Yes 0 511 Z 0 to Z 7 |
||
Counting range | |||
— adjustable — lower limit — upper limit |
Yes 0 999 |
||
IEC counter | |||
● present ● Type ● Number |
Yes SFB Unlimited (limited only by RAM capacity) |
||
S7 times | |||
● Number | 512 | ||
Retentivity | |||
— adjustable — lower limit — upper limit — preset |
Yes 0 511 No retentivity |
||
Time range | |||
— lower limit | 10 ms | ||
— upper limit | 9 990 s | ||
IEC timer | |||
● present ● Type ● Number |
Yes SFB Unlimited (limited only by RAM capacity) |
||
Data areas and their retentivity | |||
Retentive data area (incl. timers, counters, flags), max. | 256 kbyte | ||
Flag | |||
● Size, max. ● Retentivity available ● Retentivity preset ● Number of clock memories |
4 096 byte Yes; From MB 0 to MB 4 095 MB 0 to MB 15 8; 1 memory byte |
||
Data blocks | |||
● Retentivity adjustable ● Retentivity preset |
Yes; via non-retain property on DB Yes |
||
Local data | |||
● per priority class, max. | 32 768 byte; Max. 2048 bytes per block | ||
Address area | |||
I/O address area | |||
● Inputs ● Outputs |
8 192 byte 8 192 byte |
||
of which distributed | |||
— Inputs — Outputs |
8 192 byte 8 192 byte |
||
Process image | |||
● Inputs ● Outputs ● Inputs, adjustable ● Outputs, adjustable ● Inputs, default ● Outputs, default |
8 192 byte 8 192 byte 8 192 byte 8 192 byte 1 024 byte 1 024 byte |
||
Default addresses of the integrated channels | |||
— Digital inputs — Digital outputs |
66 66 |
||
Subprocess images | |||
● Number of subprocess images, max. | 1; With PROFINET IO, the length of the user data is limited to 1600 bytes | ||
Digital channels | |||
● Inputs — of which central ● Outputs — of which central |
65 536 256 65 536 256 |
||
Analog channels | |||
● Inputs — of which central ● Outputs — of which central |
4 096 64 4 096 64 |
||
Hardware configuration | |||
Number of expansion units, max. | 0 | ||
Number of DP masters | |||
● integrated ● via CP |
2; 1 DP and 1 DP (drive) 2; for DP |
||
Number of operable FMs and CPs (recommended) | |||
● FM ● CP, PtP ● CP, LAN |
8 8 8 |
||
Rack | |||
● Racks, max. ● Modules per rack, max. |
1 8 |
||
Time of day | |||
Clock | |||
● Hardware clock (real-time) ● retentive and synchronizable ● Backup time ● Deviation per day, max. ● Behavior of the clock following POWER-ON ● Behavior of the clock following expiry of backup period |
Yes Yes 6 wk; At 40 °C ambient temperature 10 s; Typ.: 2 s Clock continues running after POWER OFF the clock continues at the time of day it had when power was switched offoff |
||
Operating hours counter | |||
● Number | 4 | ||
● Number/Number range | 0 to 3 | ||
● Range of values | 0 to 2^31 hours (when using SFC 101) | ||
● Granularity | 1 h | ||
● retentive | Yes; Must be restarted at each restart | ||
Clock synchronization | |||
● supported | Yes | ||
● to MPI, master | Yes | ||
● to MPI, slave | Yes | ||
● to DP, master | Yes | ||
● to DP, slave | Yes; Only time-of-day slave | ||
● in AS, master | Yes | ||
● in AS, slave | Yes | ||
● on Ethernet via NTP | Yes; As client | ||
Digital inputs | |||
Number of digital inputs | 4 | ||
● of which inputs usable for technological functions | 4 | ||
Input characteristic curve in accordance with IEC 61131, | Yes | ||
type 1 | |||
Number of simultaneously controllable inputs | |||
horizontal installation | |||
— up to 40 °C, max. | 4 | ||
— up to 60 °C, max. | 4 | ||
vertical installation | |||
— up to 40 °C, max. | 4 | ||
Input voltage | |||
● Rated value (DC) ● for signal "0" ● for signal "1" |
24 V -3 to +5V +15 to +30 V |
||
Input current | |||
● for signal "1", typ. | 7 mA | ||
Input delay (for rated value of input voltage) | |||
for technological functions | |||
— at "0" to "1", max. — at "1" to "0", max. |
10 µs; Typical 10 µs; Typical |
||
Cable length | |||
● shielded, max. | 1 000 m | ||
Digital outputs | |||
Number of digital outputs | 8 | ||
● of which high-speed outputs | 8 | ||
Functions | for technology functions, e.g. high-speed cam switch signals | ||
Short-circuit protection | Yes | ||
● Response threshold, typ. | 1 A | ||
Limitation of inductive shutdown voltage to | 48 V | ||
Controlling a digital input | No | ||
Switching capacity of the outputs | |||
● on lamp load, max. | 5 W | ||
Load resistance range | |||
● lower limit ● upper limit |
48 Ω 4 kΩ |
||
Output voltage | |||
● for signal "0", max. ● for signal "1", min. |
3 V; (2L+) Rated voltage -2.5 V |
||
Output current | |||
● for signal "1" rated value ● for signal "1" permissible range for 0 to 60 °C, min. ● for signal "1" permissible range for 0 to 60 °C, max. ● for signal "0" residual current, max. |
0.5 A 5 mA 0.6 A 0.3 mA |
||
Parallel switching of two outputs | |||
● for uprating ● for redundant control of a load |
No No |
||
Switching frequency | |||
● with resistive load, max. ● with inductive load, max. ● on lamp load, max. |
100 Hz 0.2 Hz; According to IEC 60947-5-1, DC-13 100 Hz |
||
Total current of the outputs (per group) | |||
horizontal installation | |||
— up to 40 °C, max. — up to 60 °C, max. |
4 A 3 A |
||
all other mounting positions | |||
— up to 40 °C, max. | 4 A | ||
Integrated high-speed cams | |||
● Switching accuracy (+/-) | 70 µs | ||
Cable length | |||
● shielded, max. | 1 000 m | ||
Analog inputs | |||
Number of analog inputs | 0 | ||
Analog outputs | |||
Number of analog outputs | 0 | ||
Encoder | |||
Connectable encoders | |||
● 2-wire sensor | No | ||
Interfaces | |||
Number of industrial Ethernet interfaces | 1 | ||
Number of PROFINET interfaces | 1 | ||
Number of RS 485 interfaces | 2 | ||
Number of RS 422 interfaces | 0 | ||
1. Interface | |||
Interface type | Integrated RS 485 interface | ||
Isolated | Yes | ||
Interface types | |||
● RS 485 ● Output current of the interface, max. |
Yes 200 mA |
||
Protocols | |||
● MPI ● PROFIBUS DP master ● PROFIBUS DP slave ● Point-to-point connection |
Yes Yes Yes No |
||
MPI | |||
● Transmission rate, max. | 12 Mbit/s | ||
Services | |||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server |
Yes Yes Yes Yes Yes No; but via CP and loadable FB Yes |
||
PROFIBUS DP master | |||
● Transmission rate, max. | 12 Mbit/s | ||
● Number of DP slaves, max. | 124 | ||
Services | |||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server — Equidistance — Isochronous mode — SYNC/FREEZE — Activation/deactivation of DP slaves — Number of DP slaves that can be simultaneously activated/deactivated, max. — Direct data exchange (slave-to-slave communication) — DPV1 |
Yes Yes No Yes; I blocks only Yes No Yes Yes Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO Yes Yes 8 Yes; as subscriber Yes |
||
Address area | |||
— Inputs, max. — Outputs, max. |
8 kbyte 8 kbyte |
||
User data per DP slave | |||
— Inputs, max. — Outputs, max. |
244 byte 244 byte |
||
PROFIBUS DP slave | |||
● Transmission rate, max. ● automatic baud rate search ● Address area, max. ● User data per address area, max. |
12 Mbit/s Yes; only with passive interface 32 32 byte |
||
Services | |||
— PG/OP communication — Routing — Global data communication — S7 basic communication — S7 communication — S7 communication, as client — S7 communication, as server — Direct data exchange (slave-to-slave communication) — DPV1 |
Yes Yes; Only with active interface No No Yes No Yes; Connection configured on one side only Yes No |
||
Transfer memory | |||
— Inputs — Outputs |
244 byte 244 byte |
||
2. Interface | |||
Interface type | Integrated RS 485 interface | ||
Isolated | Yes | ||
Interface types | |||
● RS 485 ● Output current of the interface, max. |
Yes 200 mA |
||
Protocols | |||
● MPI ● PROFIBUS DP master ● PROFIBUS DP slave ● Point-to-point connection |
No Yes; DP(DRIVE)-Master No No |
||
PROFIBUS DP master | |||
● Transmission rate, max. ● Number of DP slaves, max. |
12 Mbit/s 64 |
||
Services | |||
— PG/OP communication — Routing |
No No |
||
— Global data communication — S7 basic communication — S7 communication — Equidistance — Isochronous mode — SYNC/FREEZE — Activation/deactivation of DP slaves — DPV1 |
No No No Yes Yes No Yes No |
||
Address area | |||
— Inputs, max. — Outputs, max. |
1 024 byte 1 024 byte |
||
User data per DP slave | |||
— Inputs, max. — Outputs, max. |
244 byte 244 byte |
||
PROFIBUS DP slave | |||
● GSD file ● Transmission rate, max. |
http://support.automation.siemens.com in Product Support area 12 Mbit/s |
||
3. Interface | |||
Interface type |
PROFINET |
||
Isolated | Yes | ||
automatic detection of transmission rate | Yes; 10/100 Mbit/s | ||
Autonegotiation | Yes | ||
Autocrossing | Yes | ||
Change of IP address at runtime, supported | Yes | ||
Interface types | |||
● RJ 45 (Ethernet) ● Number of ports ● integrated switch |
Yes 2 Yes |
||
Protocols | |||
● MPI ● PROFINET IO Controller ● PROFINET IO Device ● PROFIBUS DP master ● PROFIBUS DP slave ● Open IE communication ● Web server ● Media redundancy |
No Yes; Also simultaneously with IO-Device functionality Yes; Also simultaneously with IO Controller functionality No No Yes; Via TCP/IP, ISO on TCP, and UDP Yes Yes |
||
PROFINET IO Controller | |||
● Transmission rate, max. | 100 Mbit/s | ||
Services | |||
— PG/OP communication — Routing — S7 communication — Isochronous mode — Shared device — Prioritized startup — Number of IO devices with prioritized startup, max. — Number of connectable IO Devices, max. — Of which IO devices with IRT, max. — of which in line, max. — Number of connectable IO Devices for RT, max. — of which in line, max. — Activation/deactivation of IO Devices — Number of IO Devices that can be simultaneously activated/deactivated, max. — IO Devices changing during operation (partner ports), supported |
Yes Yes Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 Yes; OB 61; isochronous mode can only be used alternatively on PROFIBUS DP or PROFINET IO Yes Yes 32 128 64 64 128 128 Yes 8 Yes |
||
— Number of IO Devices per tool, max. — Device replacement without swap medium — Send cycles — Updating time |
8 Yes 250 µs, 500 µs, 1 ms, 2 ms, 4 ms 250 µs to 512 ms (depending on the operating mode, see Manual "S7- 300 CPU 31xC and CPU 31x, technical Data" for more details) |
||
Address area | |||
— Inputs, max. — Outputs, max. — User data consistency, max. |
8 kbyte 8 kbyte 1 024 byte |
||
PROFINET IO Device | |||
Services | |||
— PG/OP communication — Routing — S7 communication — Isochronous mode — IRT — PROFIenergy — Shared device — Number of IO Controllers with shared device, max. |
Yes Yes Yes; with loadable FBs, max. configurable connections: 16, max. number of instances: 32 No Yes Yes; With SFB 73 / 74 prepared for loadable PROFIenergy standard FB for I-Device Yes 2 |
||
Transfer memory | |||
— Inputs, max. — Outputs, max. |
1 440 byte; Per IO Controller with shared device 1 440 byte; Per IO Controller with shared device |
||
Submodules | |||
— Number, max. — User data per submodule, max. |
64 1 024 byte |
||
Open IE communication | |||
● Number of connections, max. ● Local port numbers used at the system end ● Keep-alive function, supported |
16 0, 20, 21, 23, 25, 80, 102, 135, 161, 443, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes |
||
Protocols | |||
PROFIsafe | Yes | ||
Redundancy mode | |||
Media redundancy | |||
— Switchover time on line break, typ. — Number of stations in the ring, max. |
200 ms; PROFINET MRP 50 |
||
Open IE communication | |||
● TCP/IP — Number of connections, max. — Data length for connection type 01H, max. — Data length for connection type 11H, max. — several passive connections per port, supported ● ISO-on-TCP (RFC1006) — Number of connections, max. — Data length, max. ● UDP — Number of connections, max. — Data length, max. |
Yes; via integrated PROFINET interface and loadable FBs 16 1 460 byte 32 768 byte Yes Yes; via integrated PROFINET interface and loadable FBs 16 32 768 byte Yes; via integrated PROFINET interface and loadable FBs 16 1 472 byte |
||
Web server | |||
● supported ● User-defined websites ● Number of HTTP clients |
Yes Yes 5 |
||
communication functions / header | |||
PG/OP communication | Yes | ||
Data record routing | Yes | ||
Global data communication | |||
● supported | Yes | ||
● Number of GD loops, max. ● Number of GD packets, max. ● Number of GD packets, transmitter, max. ● Number of GD packets, receiver, max. ● Size of GD packets, max. ● Size of GD packet (of which consistent), max. |
8 8 8 8 22 byte 22 byte |
||
S7 basic communication | |||
● supported ● User data per job, max. ● User data per job (of which consistent), max. |
Yes 76 byte 76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
||
S7 communication | |||
● supported ● as server ● as client ● User data per job, max. |
Yes Yes Yes; via integrated PROFINET interface and loadable FB or via CP and loadable FB See online help of STEP 7 (shared parameters of the SFBs/FBs and of the SFCs/FCs of S7 Communication) |
||
S5 compatible communication | |||
● supported | Yes; via CP and loadable FC | ||
Number of connections | |||
● overall ● usable for PG communication — reserved for PG communication — adjustable for PG communication, min. — adjustable for PG communication, max. ● usable for OP communication — reserved for OP communication — adjustable for OP communication, min. — adjustable for OP communication, max. ● usable for S7 basic communication — reserved for S7 basic communication — adjustable for S7 basic communication, min. — adjustable for S7 basic communication, max. ● usable for S7 communication — reserved for S7 communication — adjustable for S7 communication, min. — adjustable for S7 communication, max. ● total number of instances, max. ● usable for routing |
32 31 1 1 31 31 1 1 31 30 0 0 30 16 0 0 16 32 X1 as MPI: max. 10; X1 as DP master: max. 24; X1 as DP slave (active): max. 14; X2 as PROFINET: 24 max. |
||
S7 message functions | |||
Number of login stations for message functions, max. | 32; Depending on the configured connections for PG/OP and S7 basic communication | ||
Process diagnostic messages | Yes | ||
simultaneously active Alarm-S blocks, max. | 300 | ||
Test commissioning functions | |||
Status block |
Yes; Up to 2 simultaneously |
||
Single step | Yes | ||
Number of breakpoints | 4; without continuation | ||
Status/control | |||
● Status/control variable ● Variables ● Number of variables, max. — of which status variables, max. — of which control variables, max. |
Yes Inputs, outputs, memory bits, DB, times, counters 30 30 14 |
||
Forcing | |||
● Forcing ● Forcing, variables ● Number of variables, max. |
Yes Inputs, outputs 10 |
||
Diagnostic buffer | |||
● present ● Number of entries, max. — adjustable — of which powerfail-proof ● Number of entries readable in RUN, max. — adjustable — preset |
Yes 500 No 100; Only the last 100 entries are retained 499 Yes; From 10 to 499 10 |
||
Service data | |||
● can be read out | Yes | ||
Interrupts/diagnostics/status information | |||
Alarms | No | ||
Diagnostics function | No | ||
Diagnostics indication LED | |||
● Status indicator digital input (green) ● Status indicator digital output (green) |
Yes Yes |
||
Potential separation | |||
Potential separation digital inputs | |||
● between the channels and backplane bus | Yes | ||
Potential separation digital outputs | |||
● between the channels and backplane bus | Yes | ||
Isolation | |||
Isolation tested with | 500 V DC | ||
Ambient conditions | |||
Ambient temperature during operation | |||
● min. ● max. |
0 °C 60 °C |
||
configuration / header | |||
Configuration software | |||
● STEP 7 | Yes; STEP 7 V5.5 SP2 or higher and S7-Technology Option Package V4.2 SP3, S7 F Configuration Pack V5.5 SP10, S7 Distributed Safety Option Package V5.4 SP5 | ||
configuration / programming / header | |||
● Command set ● Nesting levels ● System functions (SFC) ● System function blocks (SFB) |
see instruction list 8 see instruction list see instruction list |
||
Programming language | |||
— LAD — FBD — STL — SCL — CFC — GRAPH — HiGraph® |
Yes Yes Yes Yes Yes Yes Yes |
||
Know-how protection | |||
● User program protection/password protection ● Block encryption |
Yes Yes; With S7 block Privacy |
||
Dimensions | |||
Width | 120 mm | ||
Height | 125 mm | ||
Depth | 130 mm | ||
Weights | |||
Weight, approx. | 640 g |
6ES7317-7UL10-0AB0 | 6ES7315-7TJ10-0AB0 | 6ES7318-3FL01-0AB0 |
6ES7317-7TK10-0AB0 |